6 - 61

When Check Character is set to Validate and Transmit, the scanner only
reads Plessey bar codes printed with a check character, and will transmit
this character at the end of the scanned data.

Default = No Check Charac-

ter.

Plessey Redundancy

If you are encountering errors when reading Plessey bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the
Plessey Redundancy bar code below, then scan a redundancy count
between 0 and 10 on the

Programming Chart

inside the back cover of this

manual. Then scan the

Save

bar code.

Default = 0.

Plessey Message Length

Scan the bar codes below to change the message length. Refer to

Message Length Description

(page 6-2) for additional information. Mini-

mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.

* No Check Character

Validate and Transmit

Validate, but Don’t Transmit

Plessey Redundancy

Minimum Message Length

Maximum Message Length