Scanner-bioptic packet mode, Ack/nak, Communication timeout – Honeywell VOYAGER 1250G User Manual

Page 52

Advertising
background image

2 - 28

Scanner-Bioptic Packet Mode

Packet Mode On must be scanned to set the scanner’s format so it is com-
patible with a bioptic scanner.

Default = Packet Mode Off.

ACK/NAK

After transmitting data, the scanner waits for an ACK character (hex 06) or
a NAK character (hex 15) response from the host. If ACK is received, the
communications cycle is completed and the scanner looks for more bar
codes. If NAK is received, the last set of bar code data is retransmitted and
the scanner waits for ACK/NAK again. Turn on the ACK/NAK protocol by
scanning the ACK/NAK On bar code below. To turn off the protocol, scan
ACK/NAK Off.

Default = ACK/NAK Off.

Communication Timeout

This allows you to set the length (in milliseconds) for a timeout for the host
ACK/NAK response. Scan the bar code below, then set the timeout (from
1-65535 milliseconds) by scanning digits from the

Programming Chart

,

then scanning

Save

.

Default = 2000 ms.

* Packet Mode Off

Packet Mode On

ACK/NAK On

* ACK/NAK Off

Communication Timeout

Advertising