Manual activation laser timeout - button settings, Manual activation laser timeout, Button settings -10 – Honeywell VOYAGER 1250G User Manual

Page 62

Advertising
background image

3 - 10

good read. If you scan Do Not End Manual Activation After Good Read,
the laser remains on after a good read, but the button must be pressed to
scan the next bar code.

Default = End Manual Activation After Good Read.

Manual Activation Laser Timeout -
Button Settings

You can set a timeout for the length of time the laser remains on and
attempting to decode bar codes when the button is held down, and after it
is released. Set the length (in milliseconds) for a timeout by scanning one
of the bar codes below, then setting the timeout (from 1-65535 millisec-
onds) by scanning digits from the

Programming Chart

, then scanning

Save

.

Default = Button Hold In-Stand 5000 ms, Button Hold Out-of-Stand

30000 ms, Button Release In or Out-of-Stand 0.

* End Manual Activation After

Good Read Out-of-Stand

Do Not End Manual Activation
After Good Read Out-of-Stand

* End Manual Activation After

Good Read In-Stand

Do Not End Manual Activation

After Good Read In-Stand

Laser Timeout - Button

Release In-Stand

Laser Timeout - Button Hold

In-Stand

Laser Timeout - Button

Release Out-of-Stand

Laser Timeout - Button Hold

Out-of-Stand