2 - 13

Hardware Flow Control

When hardware flow control is

On, the software checks for a CTS signal before

sending data. This option is useful when your application supports the CTS
signal.

Software Flow Control

This allows control of data transmission from the Imager using software
commands from the host device. When this feature is turned

Off, no data flow

control is used. When Data Flow Control is turned

On, the host device suspends

transmission by sending the XOFF character (DC3, hex 13) to the Imager. To
resume transmission, the host sends the XON character (DC1, hex 11). Data
transmission continues where it left off when XOFF was sent.