IMAGETEAM™ 4410/4710 User’s Guide

Note: Code 93 must be enabled to use this example.

You would set up the sequence editor with the following command line:

SEQBLK62999941FF6A999942FF69999943FF

The breakdown of the command line is shown below:

SEQBLKsequence editor start command
62

code identifier for Code 39

9999 code length that must match for Code 39, 9999 = all lengths
41

start character match for Code 39, 41h = “A”

FF

termination string for first code

6A

code identifier for Code 128

9999 code length that must match for Code 128, 9999 = all lengths
42

start character match for Code 128, 42h = “B”

FF

termination string for second code

69

code identifier for Code 93

9999 code length that must match for Code 93, 9999 = all lengths
43

start character match for Code 93, 43h = “C”

FF

termination string for third code

Require Output Sequence

When an output sequence is

Required, all output data must conform to an edited

sequence or the scanner will not transmit the output data to the host device.
When it’s

On/Not Required, the scanner will attempt to get the output data to

conform to an edited sequence, but if it cannot, the scanner transmits all output
data to the host device as is.