Addenda timeout, Ean/jan-13 addenda separator, Ean/jan-13 redundancy – Honeywell VOYAGER 1200G User Manual

Page 146

Advertising
background image

6 - 52

Addenda Timeout

You can set a time during which the scanner looks for an addenda. If an
addenda is not found within this time period, the data can be either trans-
mitted or discarded, based on the setting you are using for

EAN/JAN-13

Addenda Required

. Set the length (in milliseconds) for this timeout by

scanning the bar code below, then setting the timeout (from 0-65535 milli-
seconds) by scanning digits from the

Programming Chart

, then scanning

Save

.

Default = 100.

Note: The Addenda Timeout setting is applied to all addenda and coupon

code searches.

EAN/JAN-13 Addenda Separator

When this feature is On, there is a space between the data from the bar
code and the data from the addenda. When turned Off, there is no space.

Default = Off.

Note: If you want to enable or disable EAN13 with Extended Coupon Code,

refer to

UPC-A/EAN-13 with Extended Coupon Code

(page 6-38).

EAN/JAN-13 Redundancy

If you are encountering errors when reading EAN/JAN-13 bar codes, you
may want to adjust the redundancy count. Redundancy adjusts the num-
ber of times a bar code is decoded before transmission, which may reduce
the number of errors. Note that the higher the redundancy count, the lon-
ger it will take to decode the bar code. To adjust the redundancy, scan the
EAN/JAN-13 Redundancy bar code below, then scan a redundancy count
between 0 and 10 on the

Programming Chart

inside the back cover of this

manual. Then scan the

Save

bar code.

Default = 0.

Addenda Timeout

* Off

On

EAN/JAN-13 Redundancy

Advertising