Output sequence editor, To add an output sequence, Other programming selections – Honeywell VOYAGER 1200G User Manual

Page 67

Advertising
background image

3 - 17

Output Sequence Editor

This programming selection allows you to program the scanner to output
data (when scanning more than one symbol) in whatever order your appli-
cation requires, regardless of the order in which the bar codes are
scanned. Reading the

Default Sequence

symbol programs the scanner to

the Universal values, shown below. These are the defaults. Be certain
you want to delete or clear all formats before you read the

Default

Sequence

symbol.

Note: If CodeGate is enabled, you must hold the button down while reading

each bar code in a sequence.

Note: To make Output Sequence Editor selections, you’ll need to know the

code I.D., code length, and character match(es) your application
requires. Use the Alphanumeric symbols on the

Programming Chart

to read these options.

To Add an Output Sequence

1. Scan the

Enter Sequence

symbol (see

Require Output

Sequence

, page 3-20).

2. Code I.D.

On the

Symbology Chart

on page A-1, find the symbology to which you

want to apply the output sequence format. Locate the Hex value for that
symbology and scan the 2 digit hex value from the

Programming Chart

(inside back cover).

3. Length

Specify what length (up to 9999 characters) of data output will be
acceptable for this symbology. Scan the four digit data length from the

Programming Chart

. (Note: 50 characters is entered as 0050. 9999 is

a universal number, indicating all lengths.) When calculating the length,
you must count any programmed prefixes, suffixes, or formatted
characters as part of the length (unless using 9999).

4. Character Match Sequences

On the

ASCII Conversion Chart (Code Page 1252)

, page A-4, find the

Hex value that represents the character(s) you want to match. Use the

Programming Chart

to read the alphanumeric combination that

represents the ASCII characters. (99 is the Universal number,
indicating all characters.)

5. End Output Sequence Editor

Scan

F

F

to enter an Output Sequence for an additional symbology, or

Save

to save your entries.

Other Programming Selections

Discard

This exits without saving any Output Sequence changes.

Advertising