III. Service Diagnosis

WARNING

1.

This unit should be diagnosed and repaired only by qualified service
personnel to reduce the risk of death, electric shock, serious injury, or fi re.

2. Risk of electric shock. Use extreme caution and exercise safe electrical

practices.

3. Moving parts (e.g., fan blade) can crush and cut. Keep hands clear.
4. Do not make any alterations to the unit. This could cause water leak, electric

shock, or fi re.

5. To help reduce the risk of electric shock, do not touch switches with damp

hands.

A. Diagnostic Procedure

The diagnostic procedure is a sequence check of the switches and sensors while operating
the unit, by using the switch open/closed display mode.

Switch Open/Closed Display Mode
The switch open/closed display mode indicates when the door switch, wash tank water level
sensor, internal booster tank water level fl oat switch, and internal booster tank backup water
level fl oat switch are open or closed.
To enter the switch open/closed display mode, use the "ON/OFF" button to turn on the
unit. Press and hold the up and down buttons for 3 seconds. The following appears in the
display:

Internal Booster Tank Backup Water Level Float Switch
Door Switch
Internal Booster Tank Water Level Float Switch
Wash Tank Water Level Sensor

Close the door and start a cycle. The display indicates whether a switch is open or closed.
When a switch is closed, its corresponding segment is illuminated in the display. See the
illustration below.
To resume the normal display, press the down button.