35

e) Internal Booster Tank Water Level Error 2 (Internal Booster Tank Water Level Float

Switch Open) (o2)

• If the internal booster tank water level fl oat switch is open and the internal booster tank

backup water level fl oat switch has remained closed for 1 minute, the internal booster tank
heaters de-energize, "o2" appears in the display, and the buzzer sounds.

• The error resets if the internal booster tank backup water level fl oat switch opens or when

the "ON/OFF" button is used to turn the unit off and then back on.

• See the chart below for possible causes and remedies.

Note: See “III.D. Float Switch Check and Cleaning.”







Internal booster tank water level float switch is
open and internal booster tank backup water
level switch has remained closed for 1 minute.

o 2

Code Error

Item Possible

Cause

Remedy

Continues (internal

booster tank heater off).

Operation

Open circuit.

Repair or replace.

Internal Booster Tank

Water Level Float

Switch

Sticking.

Check and clean. See

“III.D. Float Switch
Check and Cleaning.

Defective.

Replace.

Control Board

Connector not properly
connected.

Reconnect.

Defective.

Replace.

Defective.

Replace.

Internal Booster Tank

Backup Water Level

Float Switch

Sticking.

Check and clean. See

“III.D. Float Switch
Check and Cleaning.