f) Wash Tank Thermistor Error (H1, H2)

• If the wash tank thermistor senses a temperature at or above 231°F (111°C) (2.4kΩ), the

thermistor leads are considered shorted and the wash tank heaters de-energize, "H1"
appears in the display, and the buzzer sounds.

• If the wash tank thermistor senses a temperature at or below -6°F (-21°C) (517kΩ), the

thermistor leads are considered open and the wash tank heaters de-energize, "H2" appears
in the display, and the buzzer sounds.

• After replacing the failed component, the alarm resets.
• See the chart below for possible causes and remedies.
Note: When this error occurs, the auto fi ll cycle will not start.

Note: See “III.E. Thermistor Check” and “IV.M. Removal and Replacement of Thermistor.”









Control Board

Connector not properly
connected.

Reconnect.

Thermistor

Connector not properly
connected.

Reconnect.

Open circuit (H2).

Replace.

Thermistor senses abnormal temperature.

H 1 / H 2

Code Error

Item Possible

Cause Remedy

Continues (wash tank

heater off).

Operation

Short circuit (H1).

Replace.

Defective.

Replace.

Defective.

Replace.