B. error codes – Hoshizaki JWE-620UA-6B User Manual

Page 33

Advertising
background image

28

B. Error Codes

In the event of operation outside of normal parameters, the control board identifi es the issue
with an error code. For further service information, see "III.C. Service Flow Charts."

1. Error Code Table

Error

Code

Problem

Operation

Reset

A1

Wash Tank Auto Fill Error

Water level in wash tank does not reach

water level sensor after rinse pump has

run preset number of cycles.

Unit stops

Use "ON/OFF" button to turn the unit

off and then back on.

A2

Internal Booster Tank Auto Fill Error

In auto fi ll cycle, internal booster tank

water level fl oat switch does not close

within 10 minutes after inlet water valve is

opened.

Whole unit

stops

Use "ON/OFF" button to turn the unit

off and then back on.

A3

Wash Tank Water Level Error

Water level in wash tank goes below

water level sensor in "READY" mode or in

"STANDBY."

Auto fi ll cycle

starts

After auto fi ll cycle ends, alarm resets.

o1

Internal Booster Tank Water Level Error 1

(Internal Booster Tank Water Level Float

Switch Closed)

Both internal booster tank water level fl oat

switch and internal booster tank backup

water level fl oat switch have remained

closed for 1 minute.

Normal

(internal

booster tank

heaters off)

Use "ON/OFF" button to turn the unit

off and then back on.

o2

Internal Booster Tank Water Level Error 2

(Internal Booster Tank Water Level Float

Switch Open)

Internal booster tank water level fl oat

switch is open and internal booster

tank backup water level fl oat switch has

remained closed for 1 minute.

Normal

(internal

booster tank

heaters off)

Use "ON/OFF" button to turn the unit

off and then back on.

H1

Wash Tank Thermistor Error (short)

Thermistor senses abnormal temperature

(at or above 231°F (110°C)).

Normal

(wash tank

heaters off)

After replacing failed component,

alarm resets.

H2

Wash Tank Thermistor Error (open)

Thermistor senses abnormal temperature

(at or below -6°F (-21°C)).

Normal

(wash tank

heaters off)

After replacing failed component,

alarm resets.

H3

Internal Booster Tank Thermistor Error

(short)

Thermistor senses abnormal temperature

(at or above 231°F (110°C)).

Normal

(internal

booster tank

heaters off)

After replacing failed component,

alarm resets.

Advertising