Hardware flow control, Ignore parity errors – HP QMS 1660E User Manual

Page 69

Advertising
background image

Interfaces

4-37

Printer Configuration

Hardware Flow Control

Controls the flow of data between the printer and the host.

Ignore Parity Errors

Specifies how the printer should handle parity errors.

Menu

Administration/Communications/Serial/Hdwe Flow Ctl

Choices

CTS
DSR
DSR POL
DTR
DTR POL
RTS

Off, on
Off, on
Normal, reverse
Off, on
Normal, reverse
Off, on

Defaults

CTS
DSR
DSR POL
DTR
DTR POL
RTS

Off
Off
Normal
On
Normal
Off

Notes

If the host uses hardware flow control, set this option to match
the type used by the host.

Baud rates of 19200 and 38400 require that both RTS and
CTS hardware flow control ((Administration/Communications/
Serial/Hdwe Flow Ctl menu) be selected. These baud rates do
not support XON/XOFF software flow control) Rcv Sw Flow
Ctl).

To download print system software to flash memory via the
serial port, RTS and CTS must both be set to On also, and the
cable pinouts must be connected as shown in appendix B,
“Technical Specifications.”

Menu

Administration/Communications/Serial/Ignore Par. Err.

Choices

Off—Ignore parity errors. The printer prints its best

interpretation of the character(s) affected by the error.

On—Don’t ignore parity errors. The printer replaces the

character(s) affected by the error with a question mark.

Default

Off