Model OFE-321,322



1-4. WARNINGS AND
ERROR MESSAGES
(Continued)

ERROR CODES

DISPLAY

CAUSE

CORRECTION


“E-4”

PC board too hot

Check ventilation louvers on side of fryer

“CPU TOO

for obstructions; if louvers are clear,

HOT”

have PC board checked

“E-5”

Controls sensing 405°F

Have heat components and temperature

“FRYER TOO

or above

probe checked

HOT”


“E-6”

(

A

or

B

)

Faulty temperature probe or

Have temperature probe and connection

“FRYER

connection

checked

TEMP

SENSOR

FAILED”


“E-10”

Shortening temperature too hot,

Reset high limit (see Operating Components

“HIGH LIMIT

drain valve opened while heat was

Section); check shortening temperature for

TRIPPED”

on, or faulty high limit

overheating; have heat components checked

if high limit continues to trip.


“E-15”

Drain is open or faulty microswitch

Close drain; have drain microswitch

“DRAIN IS

checked if error code persists

OPEN”

“E-25”

Wrong or faulty elements or wiring

Have electrical supply, wiring, and elements

“HEAT AMPS

problem

checked

WERE TOO

HIGH”

Because of the seriousness of this

error code, turn the POWER switch

off and back on to cancel

“E-26”

Faulty contactors or PC board

Have the contactors and PC board checked

“HEAT AMPS

ARE LOCKED

ON”

This error code could be displayed

even with the POWER switch turned

off. Unplug fryer or shut off the

wall circuit breaker to disconnect

electrical power to fryer.






1-6