Error codes – Henny Penny OFE-321 User Manual

Page 11

Advertising
background image

Model OFE-321,322



3-5. WARNINGS AND
ERROR MESSAGES
(Continued)

ERROR CODES

DISPLAY CAUSE

CORRECTION


“E-41”

Memory scrambled; an individual

Turn the POWER switch off and back

“SYSTEM

product program may be scrambled:

on; if error code persists, have the

DATA LOST”

Ex: “E-41 -2- DATA LOST”; this

PC board checked or re-initialized

means product #2 program is

scrambled

“E-46”

Faulty eprom or PC board

Turn the POWER switch OFF and back

“DATA SAVE

on; if error code persists, have the

FAILED”

PC board checked or re-initialized

“E-47”

Failure of 12 volt DC supply

Turn the COOK/PUMP switch OFF and back

“ANALOG

on the I/O board

to COOK; if the and DO NOT

SYSTEM

OR 12 VOLT

light up when the 8888’s are displayed, have the

FAILED”

I/O board replaced


Amp sensors plugged in backwards

Have positions of amp sensors checked


Faulty PC board

Have control panel replaced


“E-48”

Failure of 12 volt DC supply

Turn the COOK/PUMP switch OFF and back

INPUT

on the I/O board

to COOK; if the and DO NOT

SYSTEM

ERROR”

light up when the 8888’s are displayed, have the

I/O board replaced


Faulty PC board

Have control panel replaced


“E-70”

Faulty POWER switch

Have POWER switch checked, along

“PWR SW

or switch wiring; faulty

with its wiring; have I/O board checked

OR WIRES

I/O

board

FAILED”

“E-92”

Blown 24 volt controller fuse, or

Have the 14-pin cable connector checked or

“24 VOLT

bad 14-pin cable connection

have the fryer checked for a short to ground

FUSE”

in components such as the drain switch,

or high limit and wiring






405