1-3. TROUBLESHOOTING(Continued)

PROBLEM

CAUSE CORRECTION


Heating of

• Low or improper

• Use a meter and check the receptacle

shortening too

voltage (elec. unit)

voltage against the data plate

slow

• Weak or burnt out

• Check heating elements per Heating

elements (elec. unit)

Elements Section

• Wire(s) loose

• Tighten

• Burnt or charred

• Replace wire and clean connectors

wire

connection

• Faulty contactor

• Check contactor per Heating Contactors

Section

Shortening

• Temperature probe

• Calibrate temperature probe if ± 10° off;

overheating

needs calibration

if more than

± 10° off, replace temperature

probe


• Mercury contactor

• Check mercury contactor for not opening;

stuck closed

replace if necessary (elec. unit)


• Bad control board

• Replace control board if heat indicator stays

on past ready temperature


Foaming or boiling

• Water in shortening • At end of cook cycle, drain shortening and

over of shortening

clean

• Improper or bad

• Use recommended shortening

shortening


• Improper filtering

• Refer to the Filtering the Shortening

Section in Operator’s Manual


• Improper rinsing

• Clean and rinse the frypot; then dry

after cleaning fryer

thoroughly