Model OFE-321,322




2-12. HIGH TEMPERATURE
LIMIT CONTROL

The electric units, models OFE-321/2/3/4, use the same high

temperature control limits as the gas units, but the mounting of the

capillary tube is different on the electric units compared to the gas

units.


Checkout:

Use the same procedure as in the High Limit Temperature Control

(Gas)

Section.



Use replacement high limit, part no. 60241, 425 degree.


Replacement:


To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle, to the frypot

to be worked on. Be aware the other controls will have

power.

1. Drain the shortening from the frypot.


2. Remove control panel.


3. Loosen small inside screw nut on capillary tube.


4. Remove capillary bulb from bulb holder inside the frypot.


5. Straighten the capillary tube.


6. Remove larger outside nut that threads into pot wall.


7. Remove the two screws that secure the high limit to the high

limit

bracket.


8. Remove the defective control from the control panel area.