1-3. TROUBLESHOOTING
(Continued)

PROBLEM

CAUSE CORRECTION


Shortening will not

• Drain valve clogged • Open valve, force cleaning brush through

drain from frypot

with crumbs

drain

• Drain valve will not • Replace cotter pins in valve coupling

open by turning

handle


Filter motor runs

• Pump clogged

• Remove pump cover and clean

but pumps shortening

slowly

• Filter line connection • Tighten all filter line connections

loose


• Solidified shortening • Clear all filter lines of solidified shortening

in

lines


Filter switch on but

• Defective switch

• Check/replace switch per Filter Switch

motor does not run

Section


• Defective motor

• Check/replace motor


• Motor thermal

• Reset thermal switch on filter motor

protector

tripped


Motor hums but

• Clogged lines or

• Remove and clean pump and lines

will not pump

pump

• Replace pump seal, rotor and rollers