2-4. POWER SWITCH

1. Remove electrical power supplied to fryer.


To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

2. Remove control panel.

3. Label and remove the wires from the switch. With test

instrument, check across the terminals of the switch with
the switch in the ON position, then in the OFF position.
With the switch in the ON position, the circuit should be
closed. With the switch in the OFF position, the circuit
should be open. If the switch checks defective, replace by
continuing with this procedure.

4. With control panel removed, and the wires off the switch, push

in on tabs on the switch to remove from panel.

5. Replace with new switch, and reconnect wires to switch.

6. Replace the control panel.

2-5. TRANSFORMER

The transformer reduces voltage down to accommodate those
components with low voltage.

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

2. Remove the control panel as discussed in Complete Control Panel

Replacement Section.


3. Squeeze on the wire connector at the I/O board assembly to

disconnect the wires from the transformer.

4. Using a Phillips head screwdriver, remove the two screws

securing the transformer to the shroud.

5. Install the new transformer in reverse order.