Henny Penny OFE-321 User Manual

Page 23

Advertising
background image

Model OFE-321,322



9. Insert new 425 degree high limit, part no. 60241 and

replace

screws.

2-11

10. Uncoil capillary tube, starting at control, and insert through

pot

fitting.

To avoid electrical shock or other injury, run the capillary

line under and away from all electrical power wires and

terminals. The tube must NEVER be in such a position

where it could accidentally touch the electrical power

terminals.

11. Carefully bend the capillary bulb and tube toward bulb holder

on

heating

elements.


12. Slip capillary bulb into bulb holder on heating elements.

Pull excess capillary line from pot and tighten nut into frypot

wall.


Be sure capillary bulb of high limit is located behind

capillary bulb of thermostat. Both capillary bulbs

and bulb holders should be positioned as not to interfere

with basket or when cleaning the frypot wall, or damage to

capillary

tube

could

result.


13. With excess capillary line pulled out, tighten smaller nut hand

tight, then ¼ turn with wrench.



14. Replace front panel.



15. Refill with shortening.





409

2-12

2-12. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)