Honeywell RAPID EYE K9696V2 User Manual

Page 21

Advertising
background image

Field Work

2–3

Table 3
Panel connectors

Connector Label

Description

SERIAL PORTS

General-purpose serial ports, DB9 connector.

VIDEO INPUTS – IN

BNC connectors for video signal cable from the cameras in a
CCTV system. A Multi-Media unit has 16 video input
connections.

VIDEO INPUTS – OUT

BNC connectors to relay a video feed to either a CCTV, NTSC
or PAL monitor, VCR, or other device. The outs are capped for
delivery.

MONITOR OUTPUT 1

BNC connector; can be set to produce test pattern or a
camera tour. Also called “Video spot out” on previous version
of unit.

MONITOR OUTPUT 2

BNC connector; inoperative for this release.

MOUSE

For standard mouse (supplied)

KEYBOARD

For keyboard (optional)

TELCO

RJ-11 connector to Multi-Media unit’s modem

USB PORT

Inoperative.

PARALLEL PORT

Inoperative.

LAN

RJ-45 connector to unit’s 10/100 BT network card

AUDIO IN/OUT

Soundcard connectors

MIC IN

DISABLED; use AUDIO IN.

ALARM INPUTS

Screw terminal connectors for input and ground*
connections, to interface with devices such as alarms. TTL
type: minimum high level of +2.4 volts; maximum low level of
+0.4 volts.

CONTROL OUTPUTS

Screw terminal connectors for output and ground*
connections, to interface with devices such as: lights, sirens,
locks, and so on. TTL type. The outputs do not directly drive
devices; they control relays that do so.

* Control I/O must be referenced to the ground of the Multi-Media unit.

USB port and Printer port

The USB port and Printer port at the back of the REMM unit are for future use.

Do not connect USB devices or a printer to a Multi-Media unit.

2.2 Temperature

Honeywell recommends that a unit be operated in a non-condensing environment, in
temperatures ranging from 40° F to 104°F (or 5°C to 40°C).