Honeywell RAPID EYE K9696V2 User Manual

Page 66

Advertising
background image

Multi-Media Unit: Installation Instructions

5–8

Table 14
Sensor hardware

Acronym Sensor

Input

Implication

NO

Normally Open

input is active when switch goes ON

NC

Normally Closed

input is active when switch goes OFF

EOL

End of Line

input is active when switch goes ON, or if
wires to the alarm sensor are cut

5.7 Control

Outputs

Purpose

A View operator can activate outputs.

Up to 24 mA can be drawn at each output.

Cable

Use hookup wire in the 20-gauge range to connect the outputs to relay triggered devices
(locks, gates, warning sirens and so on) to a Multi-Media unit.

Tools

You may need:

a slot screwdriver—supplied. The screws are slightly smaller than those for a

1/8" screwdriver.

a wire stripper.

Connector

1.

From the hookup wires’ tips, strip approximately 0.6 cm (1/4 inch) of insulation.

2.

Insert each relay control wire to the screw-type, terminal connector on the
CONTROL OUTPUTS terminal strip: one wire to ground and the other wire to
the numbered connection you choose.

To avoid short-circuits, ensure that bare wire is not visible at the rear panel.

5.8 System

Monitoring

Fault relay

A Multi-Media unit can be monitored for failure:

to function

to report alarms

Should such a failure last more than 19 minutes, the FAULT RELAY is triggered.

Advertising