Honeywell RAPID EYE K9696V2 User Manual

Page 64

Advertising
background image

Multi-Media Unit: Installation Instructions

5–6

5.5 Alarm

Sensors

Tools

You need:

a slot screwdriver—supplied. The screws are slightly smaller than those for a

1/8" screwdriver.

- and -

a wire stripper.

Cable

To connect alarm-type hardware to a Multi-Media unit, use hookup wire in the 20-gauge
range.

!52 To connect an alarm sensor

1.

From the alarm wires’ tips, strip approximately 0.6 cm (1/4 inch) of insulation.

2.

Insert each alarm wire into the screw-type, terminal connector on the ALARM
terminal strip: one wire to the numbered terminal connection and the other wire
to ground.

To avoid short-circuits, ensure that bare wire is not visible at the rear panel.

5.6

Inputs for Sensors

!53 To configure inputs

1. Using

View, start a maintenance session for the Rapid Eye site. Please wait until

the “System Operational” message is displayed.

2. Click

the

Events tab. More tabs are displayed.

3. Click

the

Inputs tab.

4.

Next to an input reported as “in use” by an installer, type the name of the input
in the Input box. You can type a name of your choice.

5. Click

the

NO, NC or EOL button, as needed.

6.

Ignore the “Log” and “Alarm” checkboxes.

7. Click

Apply/Reset.