Venting, Damper settings top vent only – Harman Stove Company HB 38 DV User Manual

Page 24

Advertising
background image

VENTING

Only For Qualified Installers

24

Natural Gas

Propane

6 feet

2 1/2

1 to 4

12 feet

2 1/2 to 4

1 to 4

24 feet

1 to 2

1 to 4

36 feet

1

2 to 4

Natural Gas

Propane

12 feet

1 to 4

1 to 4

24 feet

1 to 4

1 to 4

36 feet

1 to 4

1 to 4

Range Of Approved Damper Settings
For 8” X 5” Vent

Range Of Approved Damper Settings
For 6

5

/

8

” X 4” Vent

A vent damper is provided on top vent models

to allow fine tuning of the draft. Too little draft will
cause flames to be too long with black tips and too
much draft will cause flames to be short and blue.

To adjust the damper, burn the unit on high with

both burners for 10 minutes or more. Adjust the vent
damper to a position in the ranges listed below that
produces the most desirable flame pattern. Note: 1
is less draft and 4 is maximum draft.

Damper Settings

Top Vent Only

Maximum Draft

Minimum Draft

Vent damper in the
number “4” position