B. wall penetration framing – Heat & Glo Fireplace 8000CF-OAK-IPI User Manual

Page 29

Advertising
background image

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09

29

A

12 in.

10 in.

B

Figure 8.6 Wall Penetration

B. Wall Penetration Framing

A*

B

57-1/2 in.

56-1/2 in.

Figure 8.5 Horizontal Venting Clearances to Combustible Materials

3 IN. TOP

CLEARANCE

HEAT

SHIELD

HEAT

SHIELD

WALL

WALL

SHIELD

FIRESTOP

1 IN. CLEARANCE

BOTTOM SIDES

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm).

The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm

to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing

heat shields must be fi eld trimmed. If wall thickness is greater than 7-1/4

in. (184 mm) a DVP-HSM-B will be required.

Combustible Wall Penetration
Whenever a combustible wall is penetrated, you must

frame a hole for the wall shield fi restop(s). The wall shield

fi restop maintains minimum clearances and prevents cold

air infi ltration. See Figure 8.6.
• The opening must be framed on all four sides using the

same size framing materials as those used in the wall

construction.

• DVP pipe - A wall shield fi restop is required on one side

only on interior walls. If your local inspector requires a

wall shield fi restop on both sides, then both wall shield

fi restops must have a heat shield (refer to Section 16.B.)

attached to them.

• See Section 10.J. for information for regarding the in-

stallation of a horizontal termination cap.

Non-Combustible Wall Penetration
If the hole being penetrated is surrounded by noncom-

bustible materials such as concrete, a hole with diameter

one inch greater than the pipe is acceptable.
Whenever a non-combustible wall is penetrated, the wall

shield fi restop is only required on one side and no heat

shield is necessary.

* Shows center of 10 in. x 12 in. vent framing hole for top venting. The

center of the hole is 1 inch above the center of the horizontal vent

pipe. With minimum vertical or 12 inch and 90º elbow.