Finishing, A. mantel and wall projections, B. facing material – Heat & Glo Fireplace 8000CF-OAK-IPI User Manual

Page 45

Advertising
background image

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09

45

A. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-

ances as specifi ed. Framing closer than the minimums list-

ed must be constructed entirely of noncombustible materi-

als (i.e., steel studs, concrete board, etc.) Failure to comply

could cause fi re.

Note: All

measurements

in inches.

Combustible Mantels

Figure 13.2 Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

Combustible Mantel Legs or Wall Projections

Figure 13.1 Minimum Vertical and Maximum Horizontal

Dimensions of Combustibles

B. Facing Material

• Metal front faces may be covered with non-combustible

materials only.

• Facing and/or fi nishing materials must not interfere with

air fl ow through louvers, operation of louvers or doors,

or access for service.

• Facing and/or fi nishing materials must never overhang

into the glass opening.

• Observe all clearances when applying combustible

materials.

• Seal joints between the fi nished wall and appliance top

and sides using a 300 ºF minimum sealant. Refer to

Figure 13.3.

WARNING! Risk of Fire! DO NOT apply combustible

materials beyond the minimum clearances. Comply with

all minimum clearances to combustibles as specifi ed in

this manual. Overlapping materials could ignite and will

interfere with proper operation of doors and louvers.

Figure 13.3 Noncombustible Facing Diagram

SEALANT MATERIAL

0 in.

FINISH WALL MATERIAL MAY BE

COMBUSTIBLE - TOP AND SIDES

0 in.

0 in.

NON-COMBUSTIBLE

BOARD

18

14-1/4

10-1/2

6-3/4

3

7-3/4

8-7/8

10

11-1/8

12-1/4

MEASUREMENTS FROM

TOP EDGE OF HOOD

1 in.

MIN.

3 in.

MIN.

3 ft.

MAX.

TOP VIEW

13

Finishing

Advertising