2 - 14

Serial Triggering

This provides a means of sending a serial trigger command to start and stop
decoding. When this feature is turned

Off, the Imager will not respond to serial

trigger commands. When serial triggering is turned

On, the Imager requires a

serial trigger character to activate scanning and decoding. The unit continues to
scan and decode until the

Trigger Off character turns off the scanner, a time out

occurs, or a bar code is decoded.

On the "Decimal to Hex to ASCII Conversion Chart" on page 2-36, find the hex
characters you want to use to turn the trigger on and off. Locate the decimal
values for those characters and scan the 2 digits for each one from the
Programming Chart in the back of this manual.

When Serial Triggering is On, the default Trigger On decimal character is 18 (hex
12, DC2), and the default Trigger Off decimal character is 20 (hex 14, DC4).

A one to three digit decimal number and Save are required after reading
this programming symbol. See "Decimal to Hex to ASCII Conversion
Chart" on page 2-36
, and the Programming Chart (inside back cover).

* Off

On

* Trigger Defaults

Trigger On ‡

Trigger Off ‡

Advertising