Technical data, Technical data guide values for mains connection, The hydraulic system’s pressure – Husqvarna DXR-310 User Manual

Page 50

Advertising
background image

TECHNICAL DATA

Guide values for mains connection

The power cable must be dimensioned by a qualifi ed person in accordance with national and local regulations. The
mains socket to which the machine is connected must be dimensioned for the same amperage as the machine’s
electrical socket and extension cable, e.g. a 63 A electrical socket must be preceded by a 63 A fuse.

Nominal
voltage from
power source

Min.
voltage
at machine

Cable area

Starting
current

Motor output

Setting
thermal over-
load relay

Max. cable
length during
operation

V

V

mm

2

A

kW

A

m

400

380

6

90*

50 Hz

22,0

44

163

400

380

10

90*

22,0

44

272

400

380

16

90*

22,0

44

435

460

440

6

90*

60 Hz

25,3

44

163

460

440

10

90*

25,3

44

272

460

440

16

90*

25,3

44

435

* Two phases soft start. The directly related phase can be loaded up to 30% more.

The hydraulic system’s pressure

Type of pressure

Pressure, Bar

Pump pressure

The pressure in the pipes between pump and main stop
valve. The pressure varies between pressure at rest and
max. pressure depending on which hydraulic functions
are being used.

Tool, max*

250

Rotating function

170

Outrigger down/up

250/200

Arm functions

200

Pressure cut-off

Functions equipped with pressure cut-off can never be
run at a higher pressure than that indicated. The follow-
ing functions are equipped with pressure cut-off for the
respective pressure level.

Telescopic arm

180

(External hand tool - option)

(140)

Pressure at rest

The pressure that the pump delivers when no function is
activated and the pump around valves is shut.

20 ±1

50