D. mantel projections, E. hearth extension – Hearth and Home Technologies ESCAPE-42DV User Manual

Page 10

Advertising
background image

Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08

10

NON-COMBUSTIBLE

MATERIAL

4 INCH

MINIMUM

UNLIMITED

D. Mantel Projections

Figure 3.3 Clearances to mantels or other combustibles
above

appliance

Figure 3.4 Clearances to Mantel Legs or Wall Projections

(Acceptable on both sides of opening.)

NO COMBUSTIBLES
IN THIS AREA

3-1/2 IN.

COMBUSTIBLE
FRAMING

COMBUSTIBLE
PROJECTIONS

METAL PANELS

(PROVIDED)

39 IN.

11-12 IN.

NON-COMBUSTIBLE

FACING MATERIAL

MIN. 1/2 IN. THICKNESS

TOP OF FIREPLACE
OPENING

6 IN. MIN.

12 IN.

MIN.

8 IN. MIN.

FINISH WALL
COMBUSTIBLE

3”

4-3/4”

6”

7-1/2”

9”

10-1/2”

12”

Height

above

opening

in.

6

7

8

9

10

11

12

mm 152

178

203

228

254

279

205

Horizontal

Mantel

distance

in.

3

4-3/4

6

7-1/2

9

10-1/2

12

mm

76

121

152

191

228

267

305

E. Hearth Extension

The base of the fi replace may sit on a
combustible surface. The area in front of
the fi replace must be protected by a non-
combustible hearth extension, unless the
fi replace is raised a minimum of 3 inches
above the combustible fl oor or hearth.

See fi gures 3.5 and 3.6.

12 in.

1 in. Max.

MARBLE, GRANITE, TILE OR

OTHER NON-COMBUSTIBLE

HEARTH EXTENSION

WOOD OR OTHER COMBUSTIBLE

FLOOR OR PLATFORM

BOTTOM OF FIREPLACE

FRONT EDGE

OF ASH LIP

FRONT EDGE

OF ASH LIP

COMBUSTIBLES UP TO

1 INCH THICK ALLOWED

UNDER THE OPENING

4 INCH

BOTTOM

OF FIREPLACE

1 INCH

(BUILT INTO UNIT)

3 INCH MIN.

WOOD OR OTHER

COMBUSTIBLE

FLOOR OR PLATFORM

MAY BE

COMBUSTIBLE

MATERIAL

Figure 3.5 Fireplace sitting on combustible surface.

Figure 3.6 Fireplace raised a minimum of 3 inches away from combustible surface.

Advertising