Top vent - vertical termination no elbow, Two elbows, 3 ft. min. (914mm) – Hearth and Home Technologies ESCAPE-42DV User Manual

Page 16

Advertising
background image

Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08

16

2. Top Vent - Vertical Termination

No Elbow

Figure 5.6

Figure 5.7

Two Elbows

V

1

V

1

= 50 ft. Max. (15.2 m)

V

1

= 3 ft. Min. (914mm)

FLUE

RESTRICTOR

FLUE RESTRICTOR

NOTE: A fl ue restrictor can
only be used in vent runs that
include no elbows and exceed
30 ft. total of straight vertical.

V

1

H

1

V

2

2 ft

610 mm

1 ft

305 mm

*

3 ft

914 mm

3 ft

914 mm

*

4 ft

1.2 m

4 ft

1.2 m

*

5 ft

1.5 m

9 ft

2.7 m

*

6 ft

1.8 m

12 ft

3.7 m

*

V

1

+ V

2

+ H

1

= 50 ft (15.2 m) Max.

*No specifi c restrictions on this value EXCEPT

V

1

+ V

2

+ H

1

cannot exceed 60 ft (18.3 m).

After V

1

= 6 ft, then H

1

Max.= V

1

x 2

Note: Must have a 24 inches
minimum vertical vent before
attaching any elbow to the unit.

NOTE: A fl ue restrictor can
only be used in vent runs that
include no elbows and exceed
30 ft. total of straight vertical.