Warning – Hearth and Home Technologies ESCAPE-42DV User Manual

Page 14

Advertising
background image

Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08

14

Note: Must have a 24 inches
minimum vertical vent before
attaching any elbow to the unit.

V

1

H

1

Figure 5.3

Figure 5.4

D. Vent Diagrams

1. Top Vent - Horizontal Termination

One Elbow

Two Elbows

H

2

H

1

V

1

INSTALLED

HORIZONTALLY

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles between ceiling fi restops.

• ALWAYS maintain specifi ed clearances around venting and fi restop systems.

• Install wall shield and ceiling fi restops as specifi ed.

Failure to keep insulation or other material away from vent pipe may cause fi re.

WARNING

V

1

Minimum

H

1

Maximum

2 ft

610 mm

7 in*

178 mm

3 ft

914 mm

2 ft

610 mm

4 ft

1.2 m

4 ft

1.2 m

5 ft

1.5 m

9 ft

2.7 m

6 ft

1.8 m

12 ft

3.7 m

7 ft

2.1 m

14 ft

4.3 m

10 ft

3.0 m

20 ft

6.1 m

20 ft

6.1 m

40 ft

12.2 m

After V

1

= 6 ft then H

1

= 2 x V ft Maximum

V

1

+ H

1

= 60 ft Maximum

*when used with approved termination caps

V

1

Minimum

H

1

+ H

2

3 ft

914 mm

18 in

457 mm

4 ft

1.2 m

3 ft

914 mm

5 ft

1.5 m

7 ft

2.1 m

6 ft

1.8 m

10 ft

3.0 m

7 ft

2.1 m

12 ft

3.7 m

10 ft

3.0 m

18 ft

5.5 m

20 ft

6.1 m

20 ft

6.1 m

After V

1

= 6 ft then H

1

= 2 x V

1

ft Maximum

V

1

+ H

1

+ H

2

= 60 ft Maximum

H

1

+ H

2

= 20 ft Maximum

Note: Must have a 24 inches
minimum vertical vent before
attaching any elbow to the unit.

NOTE: A fl ue restrictor can
only be used in vent runs that
include no elbows and exceed
30 ft. total of straight vertical.

NOTE: A fl ue restrictor can
only be used in vent runs that
include no elbows and exceed
30 ft. total of straight vertical.