Framing and clearances, Warning – Hearth and Home Technologies ESCAPE-42DV User Manual

Page 8

Advertising
background image

Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08

8

3

3

Framing and Clearances

Note:
Illustrations reflect typical installations and are FOR

DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design

preference.

Fire Risk

Provide adequate clearance:

• Around air openings

• To combustibles

• For service access

Locate appliance away from traffi c areas.

A. Selecting Appliance Location

When selecting a location for your appliance it is important to
consider the required clearances to walls (see fi gure 3.1).

Figure 3.1 Appliance Locations

NOTE: For actual appliance dimensions refer to Sec-
tion 16.

In addition to these framing dimensions, also reference the following sections:
• Clearances and Mantel Projections (Sections 3.C and 3.D)
• Vent Clearances and Framing (Section 6).

PERPENDICULAR SIDEWALL
CAN OVERLAP TO 4 INCHES
FROM OPENING ON BOTH SIDES

A

B

C

E

D

WARNING

A

B

C

D

E

Inches

57-1/2

22

91-1/2 64-3/4 45-3/4

Millimeters 1461

559

2325

1644

1162

Advertising