background image

Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08

40

F. Glass

Assembly

Handle glass doors with care.

• Inspect the gasket to ensure it is undamaged.

• Inspect the glass for cracks, chips or scratches.

• Do NOT strike, slam or scratch glass.

• Do NOT operate appliance with glass door removed,

cracked, broken or scratched.

• Replace glass door assembly as a complete appliance.

G. Screen Mesh

The pull-type fi rescreen hangs on the three hanger brack-
ets located above the glass.

H. Air Shutter Setting

This appliance has an adjustable air shutter (which con-
trols the primary air) factory set for the minimum vertical
vent run. If your installation has more than the minimum
required vertical vent length, adjustment of the air shutter
may be necessary to obtain optimal fl ame appearance.
This should be adjusted by a qualifi ed installer at the
time of installation.

Shutter Settings

NG

LP

ESCAPE42-DV

3/8 in.

N/A

ESCAPE42-DVLP

N/A

11/16 in.

WARNING

Figure 12.13 Glass Assembly

GLASS

CLIP

UPPER

LIP

Removing Glass Assembly

• Remove the ash lip that is located in front of the glass.

• Remove the side panels located in front of the glass.

• Remove the pull mesh fi rescreen by unhooking from the

fi replace.

• Pull and release the six glass latches (3 per side) located

on the sides of the glass frame.

• Grasping the upper lip with one hand and the lower lip

with the other, pull the bottom of the glass out fi rst. Guide
the bottom while letting the top drop down under the top
of the opening (see Figure 12.13).

Replacing Glass Assembly

Replace the glass door on the appliance. Pull out and
latch the six glass assembly latches into the groove on
the glass frame.