Hearth and Home Technologies ESCAPE-42DV User Manual
Page 15
Advertising
![background image](/manuals/100110/15/background.png)
Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08
15
Note: Must have a 24 inches
minimum vertical vent before
attaching any elbow to the unit.
Figure 5.5
1. Top Vent - Horizontal Termination - (continued)
Three Elbows
H
1
V
2
H
2
V
1
V
1
H
1
V
2
H
2
2 ft
610 mm
7 in
178 mm
*
H
2
Max = 2 X V
2
3 ft
914 mm
2 ft
610 mm
*
H
2
Max = 2 X V
2
4 ft
1.2 m
4 ft
1.2 m
*
H
2
Max = 2 X V
2
5 ft
1.5 m
9 ft
2.7 m
*
H
2
Max = 2 X V
2
6 ft
1.8 m
12 ft
3.7 m
*
H
2
Max = 2 X V
2
7 ft
2.1 m
14 ft
4.3 m
*
H
2
Max = 2 X V
2
10 ft
3.0 m
20 ft
6.1 m
*
H
2
Max = 2 X V
2
V
1
+ H
1
must be adhered to.
* V
2
has no specifi c restrictions EXCEPT,
H
t max
= 2 x V
t
and V
total
+ H
total
cannot exceed 60 ft Maximum
NOTE: A fl ue restrictor can
only be used in vent runs that
include no elbows and exceed
30 ft. total of straight vertical.