Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08

15

Note: Must have a 24 inches
minimum vertical vent before
attaching any elbow to the unit.

Figure 5.5

1. Top Vent - Horizontal Termination - (continued)

Three Elbows

H

1

V

2

H

2

V

1

V

1

H

1

V

2

H

2

2 ft

610 mm

7 in

178 mm

*

H

2

Max = 2 X V

2

3 ft

914 mm

2 ft

610 mm

*

H

2

Max = 2 X V

2

4 ft

1.2 m

4 ft

1.2 m

*

H

2

Max = 2 X V

2

5 ft

1.5 m

9 ft

2.7 m

*

H

2

Max = 2 X V

2

6 ft

1.8 m

12 ft

3.7 m

*

H

2

Max = 2 X V

2

7 ft

2.1 m

14 ft

4.3 m

*

H

2

Max = 2 X V

2

10 ft

3.0 m

20 ft

6.1 m

*

H

2

Max = 2 X V

2

V

1

+ H

1

must be adhered to.

* V

2

has no specifi c restrictions EXCEPT,

H

t max

= 2 x V

t

and V

total

+ H

total

cannot exceed 60 ft Maximum

NOTE: A fl ue restrictor can
only be used in vent runs that
include no elbows and exceed
30 ft. total of straight vertical.