2 transceiver unit, 3 hull unit – Furuno SEARCHLIGHT CH-250 User Manual

Page 16

Advertising
background image

6

1.2 Transceiver

Unit

1.2.1

General mounting considerations

The mounting location should be well ventilated and dry.

The unit can be mounted on bulkhead or the deck.

Secure the maintenance space shown in drawing below for ease of maintenance and

service.

The maximum cable length between the transceiver unit and the raise/lower drive unit cable

is 50 m.

The maximum cable length between the transceiver unit and the monitor (interface) unit is

10 m.

1.2.3 Mounting

method

Fasten the transceiver unit with four tapping screws (5X20, local supplied).

For bulkhead mounting, tighten upper tapping screws so there is 5 mm clearance between
bottom of screw head and bulkhead, and screw slots of the unit. Then fasten lower screws.

1.3 Hull

Unit

1.3.1

General mounting considerations

Noise and air bubbles will affect performance.

Do not turn on the equipment with the transducer exposed to air. Exposing the transducer to

air may damage it.

1.3.2

Installation position considerations

Discussion and agreement are required with the dockyard and ship owner in deciding the
location for the hull unit. When deciding the location, take into account the following points:

Select an area where propeller noise, cruising noise, bubbles and interference from

turbulence are minimal. Generally, the point at 1/3 to 1/2 of the ship’s length from the bow or
near the keel is the best. On-the-keel installation is advantageous for minimizing oil
consumption in comparison with of-the-keel. If the hull unit cannot be installed on the keel,
the center of the retraction tank should be within 1 meter of the keel to prevent a rolling
effect.