38

6. Press

[] [] to select ROLL ANGLE or PITCH ANGLE.

7. Press

[] [] to adjust (-10

°

to +10

°

).

By using a clinometer or other means, measure ship’s semi-permanent inclination angle. Take

the polarity of the angle as follows. For example, if the stern is 3

°

down, set -3

°

.

0

+ –

0

+ –

+

-

ROLL ANGLE

Starboard up

Starboard down

PITCH ANGLE Stern up

Stern down

8. Press the [MENU] key several times to close the menu.

3.5 System

Back

Up

After setting the equipment follow the procedure below to back up system settings. Backup data
can be loaded in the event of equipment trouble, to restore previous system settings.

1. Press the [MENU] key to display the user menu.

2. Press the cursor pad to select SYS at the top of the menu.

NO

YES

: SELECT

: CHANGE

MENU: END

MENU

COM1

COM2 HORZ VERT ES SHORT-CUT

SYS

GO TO SYS MENU

Display to select the system menu

3. Press

[] to select GO TO SYS MENU.

4. Press

[] to select YES.

The system menu appears.