Furuno SEARCHLIGHT CH-250 User Manual

Page 37

Advertising
background image

27

2.2.1 Synchronizing Transmission with Echo Sounder or Other

Sonar

To synchronize transmission of the CH-250 with an echo sounder or other type of sonar,
connect it as shown below.

Transceiver unit

06P0240

J3

KPI

EXT_SW

GND

3

5

6

KP OUT

+5V to 15V

GND

Sonar, E/S

TRX clamp

NH6P (local supply)

Vinyl wire (local supply)

AWG22-26

3 to 15V
possitive

Connection of transceiver unit to other sonar

Menu setting

1. Press the [MENU] key to display the user menu.

2. Operate the cursor pad to select COM1 at the top of menu display.

OFF

TX POWER

MAX

PULSELENGTH

LONG

TX RATE

10

INT REJECT

AGC

OFF

: SELECT

: CHANGE

MENU: END

REPLACE ONE OF ANY COLORS AMONG COLOR BAR WITH WHITE.(OFF)

MENU

COM1

COM2 HORZ VERT ES PRESET SYS

AUDIO LEVEL

0

User menu (COMN)

3. Press the [] to select TX RATE.

4. Press the [] to display the setting window.