2. Wiring

2.1

Wiring among Units

The figure on the next page shows wiring among units.

The signal cables are fitted with connectors. Connect the cables to the display, transceiver

and hull units referring to the interconnection diagram and the drawing on page S-1.

The power cable should be arranged locally. Use power cable type DPYCYS-2.5 (Japan

Industrial Standard cable) or equivalent cables. Attach climp on lugs as shown below.

40

5

50

Vinyl sheath

Braided shield

FV2-4(blue)

Armor

Conductor

Insulator

Inclusion

Tape

Braided shield

Sheath

Armor

Vinyl sheath

S = 2.5 mm
=15.2 mm

2

The raise/lower drive motor and breaker are different depending on ship’s mains.

Install the main switch for the sonar where it can be easily accessed. Turn off this switch

when the sonar is not being used, to reduce power consumption and to prevent the
transducer from slipping by vibration.

If D-sub connector is too large to pass through the hole on the monitor, transducer and/or

interface unit, remove the connector cover.