background image

35

RANGE-SONAR MODE

RANGE-VERTICAL MODE

RANGE-E/S MODE

ADJ MOTION SENSOR

TX FREQ ADJUST

TEST

TEST PATTERN

DEMO MODE

DEFAULT

: SELECT

: MENU DISPLAY MENU: END

SYSTEM SETTING

:

COLOR PALETTE

LANGUAGE

SYSTEM BACKUP

LOAD BACKUP DATA

HEADING OFFSET, DRAFT OFFSET

** SYSTEM MENU **

RANGE-TRACK MODE

System menu

6. Press the [] to select HEADING OFFSET, DRAFT OFFSET, and then press the [] to

display the heading offset display.

0 ˚

(-180˚ - +180˚)

HEADING

:

: CHANGE

MENU: END

** HEADING OFFSET/DRAFT OFFSET **

0.0 ˚

(0.0 - 60.0m)

DRAFT

:

: SELECT

Head offset display

7. Press the [] [] to align heading (1 step) so that the target on heading direction appears

at the twelve o’clock position.

8. Press the [] to choose draft.

9. Press the [] [] to set ship’s draft.

10. Press the [MENU] key several times to close the menu.

11. Confirm that the target on heading direction appears at the twelve o’clock position.

Soundome setting Confirmation

Set the serial number for the soundome connected, under nine-999 or over 1000.

1. Open the SYSTEM MENU following step 1 to 4 in the above.

2. Select SYSTEM SETTING, and then press the [] to open the SYSTEM SETTING 1 menu.