Frymaster KSCF18G User Manual

Page 20

Advertising
background image

KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 3: INSTALLATION INSTRUCTIONS

3-7

3.4 Gas Connections (cont.)

WARNING

Use a diluted soap solution to find potentially dangerous gas leaks when making

new connections.


B. Regulators: Gas regulators can be adjusted in the field, but no adjustments should be made

unless the regulator is out of adjustment or serious pressure fluctuations are observed.

C. Only qualified service personnel should make adjustments to the regulators.

D. Orifices: The fryer can be ordered to operate on any available gas. The correct

combination gas valve, appropriate burner orifices, and pilot burners are installed at the
factory. While the valve can be adjusted in the field, only qualified service personnel should
make any adjustments with the proper test equipment.

DANGER

If gas odors are detected, the gas supply must be shut off at the main shut-off valve.

The local gas company or FASC should be contacted immediately to fix the problem.


E. Flexible Couplings, Connectors and Casters:

1. If the fryer is to be installed with flexible couplings and/or quick-disconnect fittings, the

installer must use a heavy-duty AGA design-certified commercial flexible connector of
at least ¾" NPT (with suitable strain-relief attachments), in compliance with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69-(Latest Edition)
and Addenda Z21.69a-(Latest Edition). Quick disconnect devices must comply with the
Standard for Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z21.41-(Latest
Edition).

2. For an appliance equipped with casters, the installation shall be made with a connector

that complies with the Standard for Connectors for Movable Gas Appliances, ANSI
Z21.69, or Connectors for Moveable Gas Appliances, CAN/CGA-6.16. A quick-
disconnect device that complies with the Standard for Quick-Disconnect Devices for Use
with Gas Fuel, ANSI Z21.41, or Quick-Disconnect Devices for Use with Gas Fuel,
CANI-6.9, must be used. Under no circumstances are the connector and the quick-
disconnect device or its associated piping to be used to limit fryer movement.

3. The fryer must be restrained by means independent of the flexible coupling or connector

in order to limit the movement of the fryer. Clips are located on the back panel of the
fryer for the attachment of restraints.

Advertising