3 filtration system troubleshooting – Frymaster KSCF18G User Manual

Page 52

Advertising
background image

KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 7: TROUBLESHOOTING

7-6

7.3 Filtration System Troubleshooting


Pump won't

start.

Return valve not fully opened.

Tripped circuit breaker.

Incorrect or no line voltage.

Failed return microswitch.

Pump stops

during filtering

process. Motor

is hot.

Allow motor to cool for at least 45 minutes and then
press thermal overload switch on motor.

Pump stops

and motor is

cool.

Move filter handle to OFF. Allow oil to cool then
empty pan. Verify filter paper and screen are clean
and properly installed. Refill pan and restart
process.

Pump starts

and abruptly

stops.

Reset thermal overload.

Verify wiring harness is properly connected; a
damaged harness should be replaced by a FASC.

Pump is blocked. Call FASC for service.

Filter pan suction tube is blocked. Use a thin,
flexible wire to unclog.

Motor or 24 VAC transformer failed; call for service.

Pumping is

erratic.

Verify O-rings on pan outlet are present and in good
condition.

Verify paper and screen have been properly
installed.

Oil not being

returned to

frypot.

Solidified oil or sediment is likely clogging the return
line. Clear line.

After filtering,

fryer does not

operate

properly.

Verify drain valve is fully closed.

Advertising