Installation – FMI VSGF36NRC User Manual

Page 14

Advertising
background image

www.fmiproducts.com

121082-01K

14

INSTALLATION

Continued

WARNING: Never connect

natural gas fireplace to private

(non-utility) gas wells. This

gas is commonly known as

wellhead gas.

Installation Items Needed

Before installing fireplace, make sure you

have the items listed below.

• external regulator for propane/LP unit only

(supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection *

• sediment trap (optional)

• tee joint

• pipe wrench

• approved flexible gas line with gas con-

nector (if allowed by local codes) (not

provided)

* A equipment shutoff valve with 1/8" NPT

tap is an acceptable alternative to test gauge

connection. Purchase the optional equipment

shutoff valve from your dealer.
For propane/LP units, the installer must

supply an external regulator. The external

regulator will reduce incoming gas pressure.

You must reduce incoming gas pressure to

between 11" and 14" of water. If you do not re-

duce incoming gas pressure, heater regulator

damage could occur. Install external regulator

with the vent pointing down as shown in Figure

14. Pointing the vent down protects it from

freezing rain or sleet.

* Purchase the optional shutoff valve from

your dealer.
** Minimum inlet pressure for purpose of input

adjustment.

Figure 15 - Gas Connection

Sediment Trap

Equipment Shutoff Valve

With 1/8" NPT Tap*

3" Minimum

Cap Pipe Tee

Nipple Joint

Natural Gas

From Gas Meter

(5" W.C.** to 10.5"

W.C. Pressure)

Propane/LP

From External

Regulator

(11" W.C.** to 14"

W.C. Pressure)

CAUTION: Use only new,

black iron or steel pipe. Inter-

nally-tinned copper tubing may

be used in certain areas. Check

your local codes. Use pipe of

1/2" diameter or greater to allow

proper gas volume to fireplace.

If pipe is too small, undue loss

of volume will occur.

Installation must include an equipment shutoff

valve, union and plugged 1/8" NPT tap. Locate

NPT tap within reach for test gauge hook up.

NPT tap must be upstream from fireplace

(see Figure 15).
IMPORTANT: Install equipment shutoff valve

in an accessible location. The equipment

shutoff valve is for turning on or shutting off

the gas to the appliance.
Check your building codes for any special

requirements for locating equipment shutoff

valve to fireplaces.
Apply pipe joint sealant lightly to male NPT

threads. This will prevent excess sealant from

going into pipe. Excess sealant in pipe could

result in clogged fireplace valves. Never use

sealant on flare threads.

Propane/LP

Supply Tank

External

Regulator

with Vent

Pointing

Down

Figure 14 - External Regulator With Vent

Pointing Down

Advertising