Specifications, Technical service, Service hints – FMI VSGF36NRC User Manual

Page 30: Wiring diagram

Advertising
background image

www.fmiproducts.com

121082-01K

30

SPECIFICATIONS

Figure 47 - Remote Control Wiring Diagram

Black Connectors

Receiver

To Thermopile

White

Red

Model VSGF36NRC

• Rating (Variable): 33,000/21,500 Btu/Hr
• Type Gas: Natural Gas
• Ignition: Electronic
• Pressure Manifold: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum* 5" W.C.
• Shipping Weight:

120 lbs.

* For input adjustment

Model VSGF36PRC

• Rating (Variable): 33,000/21,500 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Pressure Manifold: 7.9" W.C.
• Inlet Gas Pressure (in. of water):

Maximum 13" W.C. Minimum* 11" W.C.

• Shipping Weight:

120 lbs.

* For input adjustment

TECHNICAL SERVICE

You may have further questions about installa-

tion, operation or troubleshooting. If so, contact

FMI PRODUCTS, LLC at 1-866-328-4537.

When calling, please have your model and

serial numbers of your firebox ready.
You can also visit FMI PRODUCTS, LLC’s

web site at

www.fmiproducts.com.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low for

propane/LP unit

You may feel your gas pressure is too low. If

so, contact your local gas supplier.

WIRING DIAGRAM

Note: For proper operation of remote control, wires from thermopile to control receiver must

be connected exactly as shown.

Advertising