1. This appliance is only for use with type of

gas indicated on rating plate. This appliance

is not convertible for use with other gases.

2. Do not place propane/LP supply tank(s)

inside any structure. Locate propane/LP

supply tank(s) outdoors (propane/LP units

only).

3. If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not

use any phone in your building

• immediately call your gas supplier from a

neighbor’s phone. Follow gas supplier’s

instructions

• if you cannot reach your gas supplier,

call the fire department

4. This fireplace shall not be installed in a

bedroom or bathroom.

5. Do not use this fireplace as a wood-

burning fireplace. Use only logs provided

with fireplace.

6. Do not add extra logs or ornaments such

as pine cones, vermiculite or rock wool.

Using these added items can cause soot-

ing. Do not add lava rock around base.

Rock and debris could fall into control

area of fireplace.

7. To prevent creation of soot, follow in-

structions in Cleaning and Maintenance,

page 25.

8. Before using furniture polish, wax, carpet

cleaner or similar products, turn heater off.

If heated, vapors from these products may

create a white powder residue within burner

box or on adjacent walls or furniture.

SAFETY

Continued

9. This fireplace needs fresh air ventilation to

run properly. This fireplace has an Oxygen

Depletion Sensing (ODS) safety shutoff

system. The ODS shuts down the fire-

place if enough fresh air is not available.

See Air for Combustion and Ventilation,

page 7. If fireplace keeps shutting off, see

Troubleshooting, page 26.

10. Do not run fireplace

• where flammable liquids or vapors are

used or stored

• under dusty conditions

11. Do not use this fireplace to cook food or

burn paper or other objects.

12. Do not use fireplace if any part has been

exposed to or under water. Immediately

call a qualified service technician to in-

spect fireplace and to replace any part of

control system and any gas control which

has been under water.

13. Do not operate fireplace if any log is

broken. Do not operate fireplace if a log

is chipped (dime-sized or larger).

14. Turn fireplace off and let cool before

servicing. Only a qualified service person

should service and repair fireplace.

15. Operating fireplace above elevations of

4,500 feet could cause pilot outage.

16. To prevent performance problems in

propane/LP units, do not use propane/LP

fuel tanks of less than 100 lbs. capacity

(propane/LP units only).

17. Provide adequate clearances around air

openings.

State of Massachusetts: The installa-

tion must be made by a licensed plumber

or gas fitter in the Commonwealth of

Massachusetts.
Sellers of unvented propane or natural

gas-fired supplemental room heaters shall

provide to each purchaser a copy of 527

CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for

bedroom and bathroom installation in the

Commonwealth of Massachusetts.

LOCAL CODES

Install and use fireplace with care. Follow all

local codes. In the absence of local codes,

use the latest edition of The National Fuel

Gas Code ANSI Z223.1/NFPA 54*.
*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are re-

quired, thermostat operation is not permitted.