Note: If adding the G8007 series brick liner

accessory, install it now. Follow instructions

in G8007 accessory kit.

CAUTION: Do not pick up

log base assembly by burner.

This could damage burner. Only

handle base by grates.

3. Route gas line (provided by installer)

from equipment shutoff valve to fireplace.

Route flexible gas supply line through one

of the access holes.

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas line

is provided to allow accessibility

from the fireplace (see Figure 17).

The flexible gas supply line con-

nection to the equipment shutoff

valve should be accessible.

4. Attach flexible gas line to gas supply (see

Figure 17). Check tightness of flexible gas

line attached to gas regulator of fireplace

(see Figure 17).

5. Check all gas connections for leaks. See

Checking Gas Connections, page 16.

6. Replace log base assembly back into

fireplace. Feed flexible gas line into fire-

place base area while replacing log base

assembly. Make sure the entire flexible

gas line is in fireplace base area. Reat-

tach log base assembly to fireplace with

screws removed in step 2.

INSTALLATION

Continued

Figure 16 - Removing Log Base

Assembly From Fireplace

Figure 17 - Attaching Flexible Gas Lines

Together

Flexible Gas Line

from Fireplace

Gas Regulator

To Fireplace

Gas Regulator

Equipment

Shutoff Valve

Provided by

Installer

Propane/LP

To External

Regulator

Natural Gas

To Gas Meter

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

We recommend that you install a sediment

trap in supply line as shown in Figure 15,

page 14. Locate sediment trap where it is

within reach for cleaning. Install in piping

system between fuel supply and fireplace.

Locate sediment trap where trapped matter

is not likely to freeze. A sediment trap traps

moisture and contaminants. This keeps them

from going into fireplace gas controls. If sedi-

ment trap is not installed or is installed wrong,

fireplace may not run properly.

CONNECTING FIREPLACE TO GAS

SUPPLY

Installation Items Needed

• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not

provided)

1. Remove fireplace screen. Remove one

screw that holds fireplace screen in place

for shipping. This screw is located near

top left side of screen. Discard screw.

Lift fireplace screen up and pull out to

remove.

2. Remove screws that attach log base

assembly to fireplace (see Figure 16).

Carefully lift up log base assembly and

remove from fireplace (see Figure 16).

Advertising