Setting the receive alarm – Furuno INMARSAT-C MOBILE EARTH STATION FELCOM 12 User Manual

Page 107

Advertising
background image

4-21

3) display log

The Display Log shows message number, priority, date and time of
transmission, LES ID and file size (in bytes) of the latest 50 received
and transmitted messages.

4) printing

Printing of a message begins (except messages with passwords) as
soon as it is received.

5) saving and filing

The DTE saves and files a receive message to the Display Message
List. (For installations with both a main and a 2nd DTE, you may
select where to store receive messages, on the system setup menu.)
The Display Message List shows the following:

Receive message no.
LES ID
Priority
File size (in bytes)
Message classification
Password for confidential messages
Date and time of transmission
Status

Setting the receive alarm

An audible alarm may be set to ring when a routine message is re-
ceived. The factory setting is OFF.

1. Press [F8] to display the Setup menu.

2. Press [6] to display the Auto Mode Setup.

Setup

7. E-Mail Setup
8. Directories
9. Configuration

Auto Mode Setup

OFF
ON
ON
OFF
ON

Auto Log Print

Receive Alarm
Auto Telex Msg Save
Auto EGC Msg Save
Data Report & Polling Print

Figure 4-28 Auto mode setup menu

3. Press [

/

] to send the cursor to the Receive Alarm line.

4. Press [Enter] to open the selection window.

5. To enable the alarm, select ON. The alarm will be released for

one second when a message is received.