2 life expectancy of major parts, 3 replacement of battery – Furuno FR-2105-B User Manual

Page 135

Advertising
background image

-5.2-

Terminal strips and
plugs in antenna
unit

Open antenna cover to check
terminal strip and plug
connections inside. Also check
the rubber gasket of antenna
covers for deterioration.

When closing antenna covers in
position, be careful not to catch
loose wires between covers and
unit.

6 months to
one year

CRT and
surrounding
components

High voltage at CRT and
surrounding components attract
dust in environment which will
cause poor insulation. Ask your
nearest FURUNO
representative or dealer to clean
internal high-voltage
components.

If CRT anode rubber cap or wire
sheath is cracked, ask your dealer
to replace it. Wait for at least 3
minutes until high voltage
components (CRT and HV
capacitors) discharge their
residual charges before accessing
them.

Terminal strips,
sockets, earth
terminal

Check for loose connections.
Check contacts and plugs for
proper seating, etc.

5.2

Life Expectancy of Major Parts

Parts

Type

Life expectancy

Remarks

Antenna motor D8G-571 (X-band) 42 rpm

D8G-516 (X-band) 24 rpm

Gears more than 10,000 h Wind load 100 kt

Magnetron

MG 5241, X-band, 12 kW

MG 5436, X-band, 25 kW

MG 5223F, S-band, 30 kW

MG 5240, S-band, 60 kW

2,000 - 3,000 h

5.3

Replacement of Battery

A battery installed on the RP board or Gyrocompass board inside the display unit help preserve
the data when the power is turned off. The life of the battery is about five years. When the battery
voltage is low, NG appears at diagnostic test for RP board. Contact your dealer for replacement.

Battery Type

Code number

RP board

ER3s

000 127 759

GC board

CR 1/2 8.L

000 103 769