8-

The illustration below shows how the auto acquisition areas are displayed on the screen. Up to
20* targets within the auto acquisition areas are acquired automatically. There is no priority in
picking up. It is recommended to use 2 zones on high speed craft.

* If 30 targets have already been acquired manually in the MAN ACQ mode (AUTO OFF on
ARPA 1 menu), only 10 more targets can be acquired automatically.

3-3.5 nm

5.5-6 nm


Predefined auto acquisition areas

Free selection of acquisition zones (Menu item: SET)

To set auto acquisition areas with trackball:

1. Press the PLOT MENU key to show the ARPA 1 menu.

2. Press the [3] key to select menu item AUTO ACQ AREA.

3. Further press the [3] key to select (or highlight) SET option.

4. Press the ENTER key to conclude your selection. At this point the AUTO ACQ SETTING

menu is displayed at the screen bottom.

[AUTO ACQ AREA SET]

1 [ARPA 1]
2 1/2

5. Press the [2] key to select menu item "1/2" and press the ENTER key. Then, you will see

the message as shown below:

[AUTO ACQ SETTING]

1 [ARPA 1]
2 1/2

SET LEFT/RIGHT BOUNDARY
CANCEL PREVIOUS AREA: CANCEL KEY