2

.

17-

Displaying and erasing past positions

To display past positions;

1. Press the [PLOT MENU] and [0] key to display the ARPA 2 menu.

[ARPA 2]

1 [ARPA 1]
2 TRIAL MODE

STATIC/DYNAMIC

3 HISTORY

OFF/1/2

4 HISTORY POINTS

5/10/20

5 HISTORY INTVL

30S/1/2/3/6MIN

6 MARK SIZE

STD/LARGE

7 GUARD, ACQUISITION STABILIZE NORTH/CRT
8 INPUT SIG CHECK
9 ARPA TRACK TEST

0 ARPA INITIAL SETTING

2. Press [3] key twice to select HISTORY ON.

3. Press the ENTER key followed by the PLOT MENU key.

The label HISTORY appears at the upper-right corner of the screen.

To erase past positions; press the [3] key twice on the ARPA 2 menu.

Selecting the number of dots and past position plot intervals

1. Press the PLOT MENU and [0] key to show the ARPA 2 menu.

2. Press the [4] key to select menu item HISTORY POINTS.

3. Further press the [4] key to select a desired number of past positions (5, 10 or 20). The

IMO-type has the selection of only 5 or 10.

4. Press the ENTER key to confirm your selection.

5. Press the [5] key to select menu item HISTORY INTERVAL.

6. Further press the [5] key to select a desired past position plot interval (0.5, 1, 2, 3 or 6

minutes).

7. Press the ENTER key to conclude your selection.

8. Press the PLOT MENU key to close the menu.

2.12 Set and Drift (Set and Rate)

Set, the direction in which a water current flows, can be manually entered in 0.1-degree steps.
Drift, in another word Rate, the speed of tide, can also be entered manually in 0.1 knot steps.