-8.2-

12 nm

9 nm

9 nm


Transmitter: normal

Receiver: normal


Transmitter: 3 dB loss
(Transmitter system has lost a
half of initial power. Suspect
magnetron and feeder system.)

Receiver: normal


Transmitter: 3 dB loss
(Transmitter system has lost a
half of initial power. Suspect
magnetron and feeder system.)

Receiver: 3 dB loss (Receiver
has lost a half of initial
sensitivity. Suspect receiver
front end, water ingress in
feeder system, etc.)