The zone has a fixed width of 0.5 nm in the radial direction (depth) and is adjustable only
within 3.0 to 6.0 nm from own ship. On the R-type, the outer and inner boundaries can be set
at any distance. On any radar type, the sector of the zone can be set anywhere between 0 and
360 degrees in any direction.

To set a target alarm zone:

1. Place the cursor (+) at point "A" (see figure below) using the trackball.

2. Press the RADAR MENU key to show the FUNCTION 1 menu.

3. Press [2] key to set start point (point "A") of the alarm zone. The message TGT ALARM 1

(or 2) SET appears at the bottom-right corner of the screen.

4. Move the cursor (+) to point "B" and press the [2] key again. Then, the target alarm zone as

illustrated is created and the label TGT ALARM 1 (or 2) appears instead of TGT ALARM
1 (or 2) SET at the lower-right corner of the screen.

Note: If you wish to create a target alarm zone having a 360-degree coverage around own
ship, set point "B" in almost the same direction (approx. ±3°) as point "A" and press the [2]
key.

If you change the range scale to less than half of the TAZ, the warning TGT ALARM 1 (or
2) OUT appears instead of TGT ALARM 1 (or 2).

5. Two alarm zones can be set as described above. Press [ENTER] and [2] keys in that order

while displaying the FUNCTION 1 menu and repeat the above steps.

000

010

020

030

040

050

060

070

080

090

100

110

120

130

140

150

160

170

180

190

200

210

220

230

240

250

260

270

280

290

300

310

320

330

340

350

TAZ

A

B

Target alarm zone (TAZ) can be set in any sector
between 3 and 6 nm on IMO-type, or anywhere on
the R-type.

When the radar has an ARPA board ARP-26, a total
of 4 alarm zones (2 each TAZ and GZ) may be set.

The 2nd TAZ or 2nd GZ is available only when the
1st TAZ or 1st GZ is valid.

Acknowledging alarm

A target entering the watch zone produces both visual (flashing) and audible (beeping) alarms.
To silence the audible alarm, press [2] key shortly on the FUNCTION 1 menu and the label
TGT ALARM 1 ACK replaces TGT ALARM 1 on the display.

This will deactivate the audible alarm but will not stop the flashing of the target in the guard
alarm zone. To reactivate the audible alarm, press [2] key again on the FUNCTIONS 1 menu.

When an external buzzer is connected, the audible alarm does not stop until deactivation of the